SAFETY BULLETIN 

Bulletin number: SB105-01

Category: Safety

Date issued: February 16, 2004

Machine models: All TEI¨ Bundle Breakers shipped since 11/01/2001

Subject: Exterior Guarding/Fencing

Back to Index
 
Description of Problem

Recommended Solution

To our valued customer:

This safety bulletin is part of an ongoing effort to provide quality service and support for all Alliance Machine Systems International, LLC products. If you need assistance or more information, please call 509-535-0356 and select option 2 for Customer Service.

Description of Problem

If the machine is not bolted to the ground and the drive side guarding is placed too close to the machine, normal vibration will cause the exit conveyor motor/gearbox to cut into the wire mesh fence.  Please refer to the attached picture. The wire mesh can potentially cut into the power cables that run to the motor causing a potentially dangerous situation for plant employees.  Figure 1 shows the general location of the problem and Figure 2 illustrates the mesh cutting into the conduit.

Figure 1: General location of problem area

 

Also, if the operator side guarding is not located correctly, the platen lockout pin cannot be fully inserted.  Figure 3 shows the general location of this lockout pin and receptacle.

Figure 2: Close-up of problem area

 

Figure 3: Location of platen lockout pin and receptacle

 

Back to top

Recommended Solutions

It is recommended that you accomplish the following actions as soon as possible, but no later than 30 days after receipt of this bulletin. 

  • If the machine is not bolted to the plant floor, do so according to the layout provided in the machine’s pre-installation package.  Please contact Customer Service if you no longer have the layout.

  • Inspect the area between the drive side fencing and the machine to verify that the guarding is positioned correctly.  If the guarding is touching the conduit/fitting, reposition it so that there is a minimum of 0.5” of clearance. 

  • If the wire mesh has damaged the conduit/fitting to any degree, replace the conduit/fitting.  Follow all proper safety procedures noted in the Bundle Breaker Operator Manual when replacing the conduit.  Please contact your supervisor if you do not understand the safety procedures.

  • If necessary, move the operator side guard panel so that the lockout pin can be easily inserted through the guarding and into the pin receptacle.  The center of the receptacle hole and the hole in the mesh should be concentric.